Emergency & exit lighting testing
6-monthly testing to AS/NZS 2293.2 for warehouses, factories, offices, retail and public buildings across Brisbane. Failed fittings replaced and your logbook kept up to date.
When the power fails, people need to get out
Emergency and exit lights have to work the moment the power goes. Batteries and lamps fail quietly, so the only way to know is to test them.
AS/NZS 2293.2 sets out routine testing, including a full discharge test every six months, with results recorded in a logbook. Fire safety auditors, insurers and building certifiers ask to see it.
Every 6-monthly visit
- Every fitting discharge tested for its rated duration.
- Exit signs checked for visibility and correct direction.
- Fittings cleaned and inspected for damage.
- Results recorded fitting by fitting, and the logbook updated on site.
- Failed batteries, lamps and fittings quoted, and replaced with your approval.
What you get Records
- Fitting registerEvery emergency light and exit sign recorded by location.
- Test resultsPass or fail for each fitting, every test.
- Updated logbookKept on site, ready for your fire safety audit.
- RemindersWe contact you before the next test falls due.
Upgrades When fittings fail
- LED emergency fittingsLonger battery life and lower running cost than old fluorescent units.
- Exit sign replacementModern LED exit signs that meet current requirements.
- Additional coverageExtra fittings where an audit finds gaps.
- Combined visitsTest and tag and RCD testing done on the same visit to save you time.
Testing with no disruption
Your normal lighting stays on the whole time. Only the emergency fittings are tested.
- Fitting registerOn the first visit we record every emergency light and exit sign by location.
- Discharge testEvery fitting runs on battery for its rated duration while we check it.
- Logbook updatedResults are recorded fitting by fitting, and your logbook is updated before we leave.
- Repairs and reminderFailed fittings are quoted and replaced, and we book the next test in six months.
Common questions
Something else you want to know? Call 0417 516 298 and talk to an electrician, not a call centre.
How often do emergency lights need to be tested?
AS/NZS 2293.2 requires a full discharge test every six months, with the results recorded in a logbook kept on site.
Will our lights go off during the test?
No. Only the emergency fittings switch to battery. Afterwards they need around 24 hours to recharge fully, so we plan the test for a quiet time.
What happens if a fitting fails?
We record it, quote a replacement battery, lamp or LED fitting, and replace it with your approval. The logbook is updated once it passes.
Can you do test and tag on the same visit?
Yes. Many of our customers have emergency lighting, test and tag and RCD testing done together on one schedule.
Often booked together
Combine services on one visit and keep everything on one schedule and one set of records.



Tell us about the job
Send the details and we’ll get back to you within one business day. For anything urgent, call.
Request a quote online
A short form with your details and what you need. Attach photos of the job and we can quote faster. It goes straight into our job system.
Request a quote or bookingPrefer to talk? Call 0417 516 298, Monday to Friday, 7:00am to 3:30pm.